Special Inspections under the International Building Code Chapter 17
Agenda
Registration: 8:00 – 8:30 am
Morning Session: 8:30 am – 12:30 pm
Lunch (On your own): 12:30 – 1:30 pm
Afternoon Session: 1:30 – 5:00 pm
Overview of Special Inspections
General program guidelines
Special inspector qualifications
Testing and inspection agency accreditation
Forms, schedules and agreements
Pre-construction meeting
Report distribution
Soil and Foundation Inspections
Existing soil conditions
Site preparation
Shallow foundations
Deep foundations
Concrete and Masonry Construction Inspections
Concrete reinforcement, placement, testing and inspection
Curing concrete, hot- and cold-weather concrete
Prestressed and precast concrete
Masonry inspection frequency and material test methods
Mortar, grout, unit placement and reinforcement
Steel Inspections
Shop fabrication
Welds
Bolted connections
Pre-engineered metal buildings
Wood, Cold-Formed Steel, Wind and Seismic Design
AWC and AISI publication references in Code
Wood and CFS material standards, fasteners and connections
Lateral framing inspection practices
Seismic resistance/isolation systems
Exterior Insulation/Finishes and Fire Resistance/Smoke Control
Exterior insulation and finish systems
Fire resistant materials and sprayed fire-resistive material
Smoke control
Material Standards and Load Tests
Design strength of materials and alternative test procedures
In-situ load tests
Pre-construction load tests
Ethics, Non-Conformances and Final Reports
Inspector authority, conflicts and “soft skills”
Discrepancy documentation, tracking and resolution
Final report, required documentation and distribution
Credits
Architects & Residential Designers
7.0 HSW CE Units
7.0 AIA HSW Learning Units
Professional Engineers
7.0 PDHs
International Code Council
.7 CEUs (Building)
Contractors
Non-Credit Continuing Ed.
Continuing Education Credit Information
This seminar is open to the public. It offers up to 7.0 HSW continuing education units to Nevada architects and residential designers. The course offers 7.0 PDHs to Nevada professional engineers. Educators and courses are not subject to preapprovalin Nevada.
This seminar is approved by the American Institute of Architects for 7.0 HSW Learning Units (Sponsor No. J885). Only full attendance can be reported to the AIA//CES.
HalfMoon Education is deemed an approved sponsor for architects in New York. HalfMoon Education is an approved continuing education sponsor for engineers in Florida, Indiana, Louisiana, Maryland, New Jersey (Approval No. 24GP00000700), New York (NYSED Sponsor No. 35), North Carolina, and North Dakota.
The International Code Council has approved this course for .7 CEUs in the specialty area of Building.
This course offers a non-credit continuing education opportunity to construction contractors. It has not been approved by any state contractor licensing board for mandatory continuing education.
Attendance will be monitored, and attendance certificates will be available after the seminar for most individuals who complete the entire event. Attendance certificates not available at the seminar will be mailed to participants within fifteen business days.
Speakers
Michael L. Savage, Sr., MCP, CBO, CFPS, CEI-M
Director of Building Safety for Marion County, FloridaMr. Savage has been in the inspection field for more than 25 years. He has been a plans examiner, a combination inspector, a chief inspector and chief building official. Mr. Savage has completed plan reviews and inspections on all types of structures from single-family dwellings, decks and sheds to micro-breweries and manufacturing/industrial facilities. He currently serves as the director of building safety/building official for Marion County, Florida. Mr. Savage holds 42 International Code Council certifications, including master code professional and certified building official. In addition, he is a NFPA-certified fire protection specialist (CFPS) and IAEI certified electrical inspector – master. He is also licensed as a building, electrical, plumbing, and mechanical inspector in the State of Maryland, and he is a qualified electrical inspector in the State of Delaware. Mr. Savage is also licensed as a building, electrical, plumbing and mechanical inspector in the State of New Mexico. He is actively involved in the code making processes and holds committee memberships on such bodies as NFPA, IAEI and UL, and he is a member of the International Code Council (ICC) Board of Directors. Mr. Savage’s past positions include the following: president of the Central New Mexico Chapter of Building Officials, president of the IAEI NM Chapter, ICC Region XI Development Committee and past president and Executive Council member of Region XI. Mr. Savage was appointed to the ICC-Evaluation Services Board of Managers in 2015, the ICC Compliance Code Action Committee (CCAC) and the ICC Code Correlation Committee (CCC). He has taught, and implemented, special inspections programs throughout the country resulting in safer, code-compliant buildings.