Agenda

Registration:                        8:00 – 8:30 am

Morning Session:                8:30 am – 12:30 pm

Lunch (On your own):         12:30 – 1:30 pm

Afternoon Session:             1:30 – 5:00 pm

Overview of Special Inspections

   General program guidelines
   Special inspector qualifications
   Testing and inspection agency accreditation
   Forms, schedules and agreements
   Pre-construction meeting
   Report distribution

Soil and Foundation Inspections

   Existing soil conditions
   Site preparation
   Shallow foundations
   Deep foundations

Concrete and Masonry Construction Inspections

   Concrete reinforcement, placement, testing and inspection
   Curing concrete, hot- and cold-weather concrete
   Prestressed and precast concrete
   Masonry inspection frequency and material test methods
   Mortar, grout, unit placement and reinforcement

Steel Inspections

   Shop fabrication
   Welds
   Bolted connections
   Pre-engineered metal buildings

Wood, Cold-Formed Steel, Wind and Seismic Design

   AWC and AISI publication references in Code
   Wood and CFS material standards, fasteners and connections
   Lateral framing inspection practices
   Seismic resistance/isolation systems

Exterior Insulation/Finishes and Fire Resistance/Smoke Control

   Exterior insulation and finish systems
   Fire resistant materials and sprayed fire-resistive material
   Smoke control

Material Standards and Load Tests

   Design strength of materials and alternative test procedures
   In-situ load tests
   Pre-construction load tests

Ethics, Non-Conformances and Final Reports

   Inspector authority, conflicts and “soft skills”
   Discrepancy documentation, tracking and resolution
   Final report, required documentation and distribution

Credits

Architects & Residential Designers
     7.0 HSW CE Units
     7.0 AIA HSW Learning Units

Professional Engineers
     7.0 PDHs

International Code Council
     .7 CEUs (Building)

Contractors
     Non-Credit Continuing Ed.

Continuing Education Credit Information

This seminar is open to the public. It offers up to 7.0 HSW continuing education units to Nevada architects and residential designers. The course offers 7.0 PDHs to Nevada professional engineers. Educators and courses are not subject to preapprovalin Nevada.

This seminar is approved by the American Institute of Architects for 7.0 HSW Learning Units (Sponsor No. J885). Only full attendance can be reported to the AIA//CES.

HalfMoon Education is deemed an approved sponsor for architects in New York. HalfMoon Education is an approved continuing education sponsor for engineers in Florida, Indiana, Louisiana, Maryland, New Jersey (Approval No. 24GP00000700), New York (NYSED Sponsor No. 35), North Carolina, and North Dakota.

The International Code Council has approved this course for .7 CEUs in the specialty area of Building.

This course offers a non-credit continuing education opportunity to construction contractors. It has not been approved by any state contractor licensing board for mandatory continuing education.

Attendance will be monitored, and attendance certificates will be available after the seminar for most individuals who complete the entire event. Attendance certificates not available at the seminar will be mailed to participants within fifteen business days.

Speakers

Michael L. Savage, Sr., MCP, CBO, CFPS, CEI-M

Director of Building Safety for Marion County, Florida

Mr. Savage has been in the inspection field for more than 25 years. He has been a plans examiner, a combination inspector, a chief inspector and chief building official. Mr. Savage has completed plan reviews and inspections on all types of structures from single-family dwellings, decks and sheds to micro-breweries and manufacturing/industrial facilities. He currently serves as the director of building safety/building official for Marion County, Florida. Mr. Savage holds 42 International Code Council certifications, including master code professional and certified building official. In addition, he is a NFPA-certified fire protection specialist (CFPS) and IAEI certified electrical inspector – master. He is also licensed as a building, electrical, plumbing, and mechanical inspector in the State of Maryland, and he is a qualified electrical inspector in the State of Delaware. Mr. Savage is also licensed as a building, electrical, plumbing and mechanical inspector in the State of New Mexico. He is actively involved in the code making processes and holds committee memberships on such bodies as NFPA, IAEI and UL, and he is a member of the International Code Council (ICC) Board of Directors. Mr. Savage’s past positions include the following: president of the Central New Mexico Chapter of Building Officials, president of the IAEI NM Chapter, ICC Region XI Development Committee and past president and Executive Council member of Region XI. Mr. Savage was appointed to the ICC-Evaluation Services Board of Managers in 2015, the ICC Compliance Code Action Committee (CCAC) and the ICC Code Correlation Committee (CCC). He has taught, and implemented, special inspections programs throughout the country resulting in safer, code-compliant buildings.