Agenda

Registration:                    8:00 – 8:30 am

Morning Session:             8:30 – 11:45 am

Lunch (On your own):       11:45 am – 12:45 pm

Afternoon Session:           12:45 – 4:30 pm

Overview of Special Inspections

   Defining special inspections

   History of IBC Code, BOCA Code and special inspections

   Role of special inspector, architect, engineer, building official, contractor

   Statement of special inspections

   Conflicts between the building code and contract documents

Structural Steel Construction – Special Inspections

   Enforcer codes (AWS, AISC 360, RSCS, SJI, SDI)

   Welding and new code requirement for ultrasonic testing (UT)

   Types of bolted connections; snug-tight, pretensioned, slip-critical

   Fabrication shop inspections – AC 472 metal building fabricators

Concrete Special Inspections – ACI 318

   Concrete reinforcement, anchor rods, post installed concrete anchors

   Concrete mixtures – verifying the approved mix design in the field

   Inspection of specified curing temperatures and techniques

   Plastic concrete tests, inspections, curing and continuous inspections

   Where to really sample concrete according to the code

Masonry Special Inspections – ACI 530 and ACI 530.1

   Submittal process and preconstruction mock-up panels

   Approving the CMU, mortar, grout, rebar prior to construction

   ASTM C 270 and ASTM C 780 – finally an answer to the confusion

   Failing masonry sands and mortar – what to do according to code

   Essential structures and non-essential structures inspection requirements

   Code requires sampling and testing of CMU from project job site

Geotechnical Engineering – Soils and Foundation Special Inspections

   Subsurface investigations and intro to geotechnical reports 101

   Implementing geotechnical report recommendations during construction

   Required special inspections in the field to verify soil bearing capacity

Special Inspections for Sprayed Fire-Resistant Materials (SFRM)

   Thickness tests on SFRM – density tests – frequency of tests

   Bond strength – adhesion/cohesion tests – frequency of tests

   Exterior insulation and finish systems (EIFS)

   Structural observations – wind resistance – seismic resistance

Credits

Architects

     6.5 Cont. Ed. Hours (HSW)
     6.5 AIA HSW Learning Units

Professional Engineers

     6.5 Cont. Ed. Hours

International Code Council

     6.5 Contact Hours

Contractors

     Voluntary CE Opportunity

Continuing Education Credit Information

This seminar is open to the public and offers up to 6.5 (HSW) continuing education hours to architects and 6.5 continuing education hours to engineers in all states. Educators and courses are not subject to preapproval in Virginia.

This event has been approved by the American Institute of Architects for 6.5 HSW Learning Units (Sponsor No. J885).

HalfMoon Education is an approved continuing education sponsor for architects in Florida and is deemed an approved sponsor in New York. HalfMoon Education is an approved continuing education sponsor for engineers in Florida, Indiana, Louisiana, Maryland, New Jersey (Approval No. 24GP00000700), New York (NYSED Sponsor No. 35), North Carolina, and North Dakota.

The International Code Council has approved this program for 6.5 contact hours (.65 CEUs) in the specialty area of Building.

This seminar offers a continuing education opportunity to construction contractors but has not been approved by any state contractor licensing entity.

Attendance will be monitored, and attendance certificates will be available after the seminar for most individuals who complete the entire program. Attendance certificates not available at the seminar will be mailed to participants within fifteen business days.

Speakers

Alan S. Tuck

Executive Director of Code Compliance and Training with Froehling & Robertson, Inc.

Mr. Tuck has more than 50 years of experience in the materials testing and construction inspection industry. He has been a code influencer. In the early 1990’s, he published a 47-page Construction Specifications Institute (CSI) monograph entitled BOCA Special Inspection Services as a learning and teaching tool for testing agencies, architects, engineers, municipalities, and building officials, etc. This document became the foundation for the original Chesterfield County, Virginia, special inspection program which today is known to be one of the best special inspection programs in the region. This CSI monograph impacted and assisted the development of special inspection programs of many other Virginia jurisdictions during the early days of BOCA and IBC. Today, Mr. Tuck is the building code “go to” guy when architects, engineers, contractors and building officials across the Mid-Atlantic have special inspection questions about their ongoing projects.

Mr. Tuck started his career with Froehling & Robertson in 1964 as a materials technician and fulfilled many duties including senior field technician, radiographic assistant, drill rig operator, laboratory technician, and structural steel inspector, quickly being promoted to branch manager of the Roanoke office in 1966. Over the next few decades, Mr. Tuck also managed F&R’s operations in Norfolk, Lynchburg, and Chesapeake, Virginia. During this time, he was designated as the company-wide manager of construction materials testing services, working in F&R’s Richmond headquarters. In the late 1990’s, Mr. Tuck took on company business development. His success in this realm led to Mr. Tuck being elevated to the role of vice president of business development. His responsibilities in this role included hiring, training, and supervising business development managers throughout the company’s Mid-Atlantic footprint. F&R was established in 1881 and is one of the oldest consulting engineering firms and testing agencies in the United States.

Mr. Tuck developed training courses related to special inspection requirements of the International Building Code (IBC) and the various statewide building codes in jurisdictions where F&R maintains operations, including Maryland, Virginia, District of Columbia and the Carolinas. He cultivated and expanded inter-company special inspections code training courses for F&R’s technicians, special inspectors and engineers. These technical code training courses formed the basis of F&R’s Continuing Education Program and Lunch & Learn Series which are comprised of building code training courses regarding soils, geotechnical engineering, concrete, masonry, sprayed fire-resistant materials, structural steel and many other disciplines. These courses are now offered to the entire Mid-Atlantic community of architects, engineers, construction professionals as well as associations, municipalities, school systems and a host of other market sectors. As F&R’s very first executive director of code compliance and training, Mr. Tuck has provided special inspections training and code training to hundreds of firms and thousands of professionals over the past decade and has dedicated this phase of his professional career to the study and instruction of the various building code changes throughout the different code cycles. He also is well versed in the major code changes of the “enforcer” codes such as AWS (welding), AISC (steel), ACI 318 (concrete), ACI 530 (masonry), in addition to the latest revisions of the International Building Code (IBC) and statewide codes within F&R’s geographical region.