Special Inspections under International Building Code Chapter 17 Seminar
Agenda
Registration: 8:00 – 8:30 am
Morning Session: 8:30 am – 12:30 pm
Lunch (On your own): 12:30 – 1:30 pm
Afternoon Session: 1:30 – 5:00 pm
Overview of Special Inspections
General program guidelines
Special inspector qualifications
Testing and inspection agency accreditation
Forms, schedules and agreements
Pre-construction meeting
Report distribution
Soil and Foundation Inspections
Existing soil conditions
Site preparation
Shallow foundations
Deep foundations
Concrete and Masonry Construction Inspections
Concrete reinforcement, placement, testing and inspection
Curing concrete, hot- and cold-weather concrete
Prestressed and precast concrete
Masonry inspection frequency and material test methods
Mortar, grout, unit placement and reinforcement
Steel Inspections
Shop fabrication
Welds
Bolted connections
Pre-engineered metal buildings
Wood, Cold-Formed Steel, Wind and Seismic Design
AWC and AISI publication references in Code
Wood and CFS material standards, fasteners and connections
Lateral framing inspection practices
Seismic resistance/isolation systems
Exterior Insulation/Finishes and Fire Resistance/Smoke Control
Exterior insulation and finish systems
Fire resistant materials and sprayed fire-resistive material
Smoke control
Material Standards and Load Tests
Design strength of materials and alternative test procedures
In-situ load tests
Pre-construction load tests
Ethics, Non-Conformances and Final Reports
Inspector authority, conflicts and “soft skills”
Discrepancy documentation, tracking and resolution
Final report, required documentation and distribution
Credits
Professional Engineers
7.0 HSW Continuing Ed. Hours
Architects
7.0 HSW Continuing Ed. Hours
7.0 AIA HSW Learning Units
International Code Council
.7 CEUs (Building)
Contractors
Non-Credit Continuing Ed.
Continuing Education Credit Information
This seminar is open to the public and offers 7.0 continuing education hours to engineers and 7.0 HSW continuing education hours to architects in all states. Educators and courses are not subject to preapproval in Tennessee.
This seminar is approved by the American Institute of Architects for 7.0 HSW Learning Units (Sponsor No. J885). Only full attendance can be reported to the AIA/CES.
HalfMoon Education is an approved continuing education sponsor for engineers in Florida, Indiana (License No. CE21700059), Maryland, New Jersey (Approval No. 24GP00000700), North Carolina, and North Dakota. HalfMoon Education is deemed an approved continuing education sponsor for New York architects.
The International Code Council has approved this event for .7 CEUs in the specialty area of Building.
This seminar offers a non-credit continuing education opportunity to construction contractors. It has not been approved by any state contractor licensing board for mandatory continuing education credit.
Attendance will be monitored, and attendance certificates will be available after the seminar for most individuals who complete the entire event. Attendance certificates not available at the seminar will be mailed to participants within fifteen business days.
Speakers
Robert Overton
RTM Consultants, Inc.Associate, RTM Consultants, Inc.
Mr. Overton has been working with building codes and life safety requirements in several capacities for 30 years. As an architectural draftsman, he has worked in several firms where his code knowledge was used to review construction documents and to prepare life safety plans and building code summaries. As a construction contract administrator, Mr. Overton was responsible for maintaining the contractual agreement between the owner and contractor. In this role, he was able to evaluate unforeseen site conditions, provide code-compliant solutions and use his knowledge of the code requirements to better evaluate alternatives proposed by the contractors. As a plans examiner, Mr. Overton worked at the Indiana Building Commissioner’s Office where he reviewed projects for all types of commercial construction. As a building code consultant within a private architectural firm, he has worked with projects for the primary and higher education markets and long-term assisted-living facilities. In the role of associate state architect, Mr. Overton was responsible for building code and life safety compliance for the hospital and retirement homes owned by the State of Indiana. Mr. Overton is a member of the National Fire Protection Association and the International Code Council. He is a certified fire protection specialist and certified fire inspector through the National Fire Protection Association. Mr. Overton is a graduate of Purdue University and has an associates degree in applied science in Architectural Technology and a bachelor’s degree in Construction Technology.