Agenda
Registration: 8:00 – 8:30 am
Morning Session: 8:30 am – 12:45 pm
Lunch (On your own): 12:45 – 1:45 pm
Afternoon Session: 1:45 – 5:00 pm
Overview of Special Inspections
Defining Special Inspections
History of IBC Code, BOCA Code and special inspections
Role of special inspector, architect, engineer, building official
Statement of special inspections; other reports & paperwork
IBC 2015 – big changes in reference codes and standards
Soil and Foundation Inspections
Geotechnical Engineering 101 – does the code require a geo report?
Subsurface investigations – verifying bearing capacity in the field
Geotechnical and soils special inspections required by the code
Soil testing & inspection in the field and lab according to the code
Concrete Special Inspections – ACI 318-14
Concrete placement, testing and special inspections
Concrete reinforcement, anchor rods, post-installed concrete anchors
First concrete code REORGANIZATION since 1971 (BIG CHANGES!)
Periodic and continuous inspections according to the code
Where and when you sample concrete according to the code
Masonry Special Inspections – ACI 530, ACI 530.1, TMS 402, TMS 602
Submittal process and preconstruction mock-up panels
Inspection requirements – essential and non-essential structures
Failing masonry sands and mortar strengths – What to do
ASTM C 270 and ASTM C 780 – Finally an answer to the confusion
Structural Steel Construction – Special Inspections
Reference codes – AISC 360, AWS, RCSC, SJI, SDI
Welding code and special inspections
Bolted connections and special inspections
Types of bolted connections: snug-tight, pretensioned, slip-critical
Special Inspections of cold-formed steel (light gauge steel)
Special Inspections for Sprayed Fire-Resistant Materials (SFRM)
Thickness tests on SFRM – density tests – frequency
Bond strength – adhesion/cohesion tests – frequency
Condition of the substrates: before and after SFRM installation
A definition of high rise building – 150 PSF or 1,000 PSF bond strength
GLANCE AHEAD – NEXT IBC Code Cycle
(Other Things That You May Not Know)
New updated wind speed maps and seismic maps in Chapter 16
New structural observations required for high rise or Risk Category IV
Does the code require special inspections on steel stairs and railing?
Reduced web thicknesses in masonry units according to ASTM C 90
Metal buildings – full pen welds must be ultrasonically tested in shop
Is the proof rolling of site soils mandated by the IBC Code
When does failing masonry mortar really pass?
Credits
Professional Engineers
7.0 PDHs
Architects
7.0 Continuing Ed. Hours (HSW)
7.0 AIA HSW Learning Units
International Code Council
.7 CEUs (Building)
Contractors
Non-Credit Continuing Ed.
Continuing Education Credit Information
This seminar is open to the public and offers 7.0 PDHs to professional engineers and 7.0 HSW (Public Protection) continuing education hours to architects in West Virginia. Educators and courses are not subject to preapproval in West Virginia.
This seminar is approved by the American Institute of Architects for 7.0 HSW Learning Units (Sponsor No. J885). Full attendance is required to report LUs to the AIA/CES.
Architects and professional engineers seeking continuing education credit in other states will be able to claim the hours earned at this seminar, in most cases. Refer to specific state rules to determine eligibility.
The International Code Council has approved this event for .7 CEUs in the specialty area of Building.
This seminar offers a non-credit continuing education opportunity to construction contractors. It has not been reviewed by any state contractor licensing entity for continuing education purposes.
Attendance will be monitored, and attendance certificates will be available after the seminar for most individuals who complete the entire event. Attendance certificates not available at the seminar will be mailed to participants within fifteen business days.
Speakers
Alan S. Tuck
Executive Director of Code Compliance and Training with Froehling & Robertson, Inc.Mr. Tuck has more than 50 years of experience in the materials testing and construction inspection industry. He has been a code influencer. In the early 1990’s, he published a 47-page Construction Specifications Institute (CSI) monograph entitled BOCA Special Inspection Services as a learning and teaching tool for testing agencies, architects, engineers, municipalities, and building officials, etc. This document became the foundation for the original Chesterfield County, Virginia, special inspection program which today is known to be one of the best special inspection programs in the region. This CSI monograph impacted and assisted the development of special inspection programs of many other Virginia jurisdictions during the early days of BOCA and IBC. Today, Mr. Tuck is the building code “go to” guy when architects, engineers, contractors and building officials across the Mid-Atlantic have special inspection questions about their ongoing projects.
Mr. Tuck started his career with Froehling & Robertson in 1964 as a materials technician and fulfilled many duties including senior field technician, radiographic assistant, drill rig operator, laboratory technician, and structural steel inspector, quickly being promoted to branch manager of the Roanoke office in 1966. Over the next few decades, Mr. Tuck also managed F&R’s operations in Norfolk, Lynchburg, and Chesapeake, Virginia. During this time, he was designated as the company-wide manager of construction materials testing services, working in F&R’s Richmond headquarters. In the late 1990’s, Mr. Tuck took on company business development. His success in this realm led to Mr. Tuck being elevated to the role of vice president of business development. His responsibilities in this role included hiring, training, and supervising business development managers throughout the company’s Mid-Atlantic footprint. F&R was established in 1881 and is one of the oldest consulting engineering firms and testing agencies in the United States.
Mr. Tuck developed training courses related to special inspection requirements of the International Building Code (IBC) and the various statewide building codes in jurisdictions where F&R maintains operations, including Maryland, Virginia, District of Columbia and the Carolinas. He cultivated and expanded inter-company special inspections code training courses for F&R’s technicians, special inspectors and engineers. These technical code training courses formed the basis of F&R’s Continuing Education Program and Lunch & Learn Series which are comprised of building code training courses regarding soils, geotechnical engineering, concrete, masonry, sprayed fire-resistant materials, structural steel and many other disciplines. These courses are now offered to the entire Mid-Atlantic community of architects, engineers, construction professionals as well as associations, municipalities, school systems and a host of other market sectors. As F&R’s very first executive director of code compliance and training, Mr. Tuck has provided special inspections training and code training to hundreds of firms and thousands of professionals over the past decade and has dedicated this phase of his professional career to the study and instruction of the various building code changes throughout the different code cycles. He also is well versed in the major code changes of the “enforcer” codes such as AWS (welding), AISC (steel), ACI 318 (concrete), ACI 530 (masonry), in addition to the latest revisions of the International Building Code (IBC) and statewide codes within F&R’s geographical region.